EasyManua.ls Logo

IBM P 615 series

IBM P 615 series
491 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HMC
Surveillance
Error
Codes
The
HMC
surveillance
error
codes
generated
only
by
the
HMC
are
listed
in
the
following
table.
Error
Code
Description
Action/
Possible
Failing
FRU
B301
0001
HMC/partition
surveillance
fault
Contact
service
support.
B301
0002
HMC/partition
surveillance
fault
Verify
the
network
between
the
HMC
and
the
partition
by
pinging
in
both
directions.
If
problems
are
found,
correct
them.
Reboot
the
HMC.
B301
0012
HMC/partition
surveillance
fault
Contact
service
support.
B301
0013
HMC/partition
surveillance
fault
Contact
service
support.
B301
0019
HMC/partition
surveillance
fault
Contact
service
support.
B301
0020
HMC/partition
surveillance
fault
Contact
service
support.
B301
0023
HMC/partition
surveillance
fault
Contact
service
support.
B301
0025
HMC/partition
surveillance
fault
Contact
service
support.
B301
0026
HMC/partition
surveillance
fault
Contact
service
support.
B301
0027
HMC/partition
surveillance
fault
1.
If
short
host
names
are
being
used
for
the
HMC
and
the
partitions,
ensure
that
the
short
host
names
are
set
up
correctly
according
to
the
instructions
in
Using
Network
Adapters
to
Communicate
with
Partitions
in
the
IBM
Hardware
Management
Console
for
pSeries
Installation
and
Operations
Guide.
Correct
any
problems
that
are
found,
then
verify
that
you
can
ping
in
both
directions
between
the
HMC
and
partitions.
2.
If
short
host
names
are
not
being
used,
or
the
previous
step
does
not
correct
the
problem,
contact
service
support.
B301
0029
HMC/partition
surveillance
fault
Contact
service
support.
B301
002B
HMC/partition
surveillance
fault
Contact
service
support.
B301
002C
HMC/partition
surveillance
fault
Contact
service
support.
B301
002D
HMC/partition
surveillance
fault
Contact
service
support.
B302
0001
HMC/partition
surveillance
fault
1.
If
short
host
names
are
being
used
for
the
HMC
and
the
partitions,
ensure
that
the
short
host
names
are
set
up
correctly
according
to
the
instructions
in
Using
Network
Adapters
to
Communicate
with
Partitions
in
the
IBM
Hardware
Management
Console
for
pSeries
Installation
and
Operations
Guide.
Correct
any
problems
that
are
found,
then
verify
that
you
can
ping
in
both
directions
between
the
HMC
and
partitions.
2.
If
short
host
names
are
not
being
used,
or
the
previous
step
does
not
correct
the
problem,
contact
service
support.
214
EserverpSeries
615
Service
Guide

Table of Contents

Related product manuals