MAP
1523:
The
SPCN
Error
Codes
Table
Directed
You
Here
and
the
Error
Code
is
1011
1B0x
A
base
system
power
supply
is
reporting
a
load
fault.
Note:
Read
the
danger
and
caution
notices
under
“Safety
Notices”
on
page
xi
before
continuing
with
this
procedure.
Perform
the
following
steps
to
isolate
the
problem.
Step
1523-1
1.
Turn
off
the
power.
2.
Disconnect
the
ac
power
cables
(dc
power
cables
in
a
dc-powered
system)
from
the
base
system
drawer.
3.
At
the
top
of
the
base
system
drawer,
remove
the
following
cards,
in
the
sequence
listed:
a.
One
quad
of
DIMMs
b.
Other
quad
of
DIMMs,
if
installed
c.
PCI
adapter
card(s)
d.
DASD
device(s)
e.
Media
bay
device(s)
4.
Reconnect
the
ac
power
cables
(dc
power
cables
in
a
dc-powered
system)
to
the
base
system
drawer.
5.
Turn
on
the
power.
Is
the
error
code
1011
1B0x
displayed?
NO
Go
to
“Step
1523-7”
on
page
109.
YES
Go
to
“Step
1523-2.”
Step
1523-2
1.
Turn
off
the
power.
2.
Disconnect
the
ac
power
cables
(dc
power
cables
in
a
dc-powered
system)
from
the
base
system
drawer.
3.
Remove
base
system
power
supply
2.
4.
Reconnect
the
ac
power
cable
(dc
power
cable
in
a
dc-powered
system)
to
the
base
system
power
supply
1.
5.
Turn
on
the
power.
Is
the
error
code
1011
1B0x
displayed?
NO
Go
to
“Step
1523-3.”
YES
Go
to
“Step
1523-4”
on
page
108
Step
1523-3
1.
Turn
off
the
power.
2.
Reinstall
base
system
power
supply
2
that
was
removed
in
“Step
1523-2.”
3.
Reconnect
the
ac
power
cable
(dc
power
cable
in
a
dc-powered
system)
to
the
base
system
power
supply
2.
4.
Turn
on
the
power.
Is
the
error
code
1011
1B0x
displayed?
Chapter
3.
Maintenance
Analysis
Procedures
(MAPs)
107

Table of Contents