NO
The
symptom
has
changed.
This
ends
the
procedure.
YES
Replace
base
system
power
supply
2,
location:
U0.1-V2.
This
ends
the
procedure.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
Step
1523-4
1.
Turn
off
the
power.
2.
Reinstall
base
system
power
supply
2
that
was
removed
in
“Step
1523-2”
on
page
107.
3.
Reconnect
the
ac
power
cable
(dc
power
cable
in
a
dc-powered
system)
to
the
base
system
power
supply
2.
4.
Disconnect
the
ac
cable
(dc
power
cable
in
a
dc-powered
system)
to
base
system
power
supply
1.
5.
Remove
base
system
power
supply
1.
6.
Turn
on
the
power.
Is
the
error
code
1011
1B0x
displayed?
NO
Replace
base
system
power
supply
1,
location:
U0.1-V1.
This
ends
the
procedure.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
YES
Go
to
“Step
1523-5.”
Step
1523-5
1.
Turn
off
the
power.
2.
Reinstall
base
system
power
supply
2
that
was
removed
in
“Step
1523-4.”
3.
Reconnect
the
ac
power
cable
(dc
power
cable
in
a
dc-powered
system)
to
the
base
system
power
supply
2.
4.
Remove
base
system
fan
3.
If
a
base
system
fan
error
code
occurs
during
this
step,
ignore
it.
5.
Turn
on
the
power.
Is
the
error
code
1011
1B0x
displayed?
NO
Replace
base
system
fan
3,
location:
U0.1-F3.
This
ends
the
procedure.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
YES
Go
to
“Step
1523-6.”
Step
1523-6
1.
Turn
off
the
power.
2.
Reinstall
base
system
fan
3
that
was
removed
in
“Step
1523-5.”
3.
Remove
base
system
fan
2.
Disregard
a
base
system
fan
error
code
if
it
occurs
during
this
step.
4.
Turn
on
the
power.
Is
the
error
code
1011
1B0x
displayed?
NO
Replace
base
system
fan
2,
location:
U0.1-F2.
This
ends
the
procedure.
Go
to
MAP
0410:
Repair
Checkout
in
the
RS/6000
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems.
YES
Go
to
“Step
1523-9”
on
page
109
108