Page #168 background imageLoading...
Page #168 background image
Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E523
Initialize
data
structures
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E537
Configuring
the
I/O
subsystem
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E53B
End
of
looking
for
next
node
port
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E540
Begin
initialization
of
I/O
drawer
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E541
Initialize
the
routing
table
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E54A
Configure
the
I/O
drawer
Replace
the
CEC
backplane,
U0.1-P1.
E560
Begin
initializing
the
I/O
drawer
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E56F
End
initializing
the
service
processor
control
chip
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E580
Begin
initializing
the
EADS
module.
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E581
Read
the
PCI
bus
configuration
header.
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E582
EADS
has
been
detected.
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E583
Running
BIST
on
the
current
EADS
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E584
Checking
function
of
current
EADS
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E585
Valid
function
of
current
EADS
detected
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
E586
Set
up
EADS
function
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
148
EserverpSeries
615
Service
Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals