Table
2.
Firmware
Checkpoints
(continued)
Checkpoint
Description
Action/
Possible
Failing
FRU
E851
Initializing
RTAS/hardware
access
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E852
Initializing
RTAS/PCI
bus
interface
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
3.
Call
service
support.
E853
Start
cable
ID
request
process
1.
Remove,
then
reapply
power
to
the
system.
2.
Go
to
“MAP
1548:
Processor
Subsystem
Problem
Isolation”
on
page
113.
3.
Call
service
support.
E854
Start
collecting
cable
IDs
1.
Remove,
then
reapply
power
to
the
system.
2.
Go
to
“MAP
1548:
Processor
Subsystem
Problem
Isolation”
on
page
113.
3.
Call
service
support.
E860
Initializing
RTAS/power
subsystem
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E861
Initializing
RTAS/PCI
bus
interface
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
3.
Call
service
support.
E870
Initializing
RTAS/logs
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E871
Initializing
RTAS/EEH
handling
interface
1.
Check
for
system
firmware
updates.
2.
Go
to
“MAP
1540:
Problem
Isolation
Procedures”
on
page
110.
3.
Call
service
support.
E872
Initializing
RTAS/error
inject
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E873
Initializing
RTAS/error
handling
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E880
Initializing
RTAS/debug
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E881
Initializing
RTAS/utility
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E882
Initializing
RTAS/softpatch
register
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
E890
Initializing
RTAS/hot-swap
interface
1.
Check
for
system
firmware
updates.
2.
Call
service
support.
Chapter
4.
Checkpoints
153

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM P 615 series and is the answer not in the manual?

IBM P 615 series Specifications

General IconGeneral
BrandIBM
ModelP 615 series
CategoryServer
LanguageEnglish

Related product manuals