EasyManua.ls Logo

IBM P 615 series

IBM P 615 series
491 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service
Request
Number
Description
and
Action
A0D-01x
Note:
Ensure
that
the
system
IPLROS
and
Service
Processor
are
at
the
latest
firmware
level
before
removing
any
parts
from
the
system.
Description:
Time-out
communication
response
from
Service
Processor.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-02x
Description:
I/O
(I2C)
general
bus
error.
Note:
If
you
are
servicing
a
9076/Nxx
system,
go
to
the
Service
Processor
Error
Log
(SVP).
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-03x
Description:
Secondary
I/O
(I2C)
general
bus
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-04x
Description:
Internal
Service
Processor
memory
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-05x
Description:
Service
Processor
error
accessing
special
registers.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-06x
Description:
Service
Processor
reports
unknown
communication
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-07x
Description:
Internal
service
processor
firmware
error
or
incorrect
version.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-08x
Description:
Other
internal
Service
Processor
hardware
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-09x
Description:
Service
Processor
error
accessing
Vital
Product
Data
EEPROM.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-10x
Description:
Service
Processor
error
accessing
Operator
Panel.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-11x
Description:
Service
Processor
error
accessing
Power
Controller.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-12x
Description:
Service
Processor
error
accessing
Fan
Sensor.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-13x
Description:
Service
Processor
error
accessing
Thermal
Sensor.
Note:
If
you
are
servicing
a
9076/Nxx
system,
go
to
the
Service
Processor
Error
Log
(SVP).Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-14x
Description:
Service
Processor
error
accessing
Voltage
Sensor.
Note:
If
you
are
servicing
a
9076/Nxx
system,
go
to
the
Service
Processor
Error
Log
(SVP).Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-17x
Description:
Service
Processor
error
accessing
serial
port.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-18x
Description:
Service
Processor
detected
NVRAM
error.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-19x
Description:
Service
Processor
error
accessing
Real
Time
Clock/Time-of-Day
Clock.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-20x
Description:
Service
Processor
error
accessing
scan
controller/hardware.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-21x
Description:
Service
Processor
detect
error
with
Time-of-Day
Clock
backup
battery.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-23x
Description:
Loss
of
heart
beat
from
Service
Processor.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
Chapter
11.
SRNs
for
Linux
379

Table of Contents