5. Replace the following, one at a time, turning off the power before replacement and
attempting to power on after replacement:
a. Service processor card
b. Power distribution card
c. Drawer indicator panel
d. Fan monitoring card
e. Both power supplies
f. I/O planar
6. Does the I/O drawer power on?
No Go to step 13 on page 99.
Yes Go to step 7.
7. Are all I/O drawers powered on (green LEDs are on for both supplies in each
I/O drawer)?
Note: The I/O drawer requires two identical power supplies to be installed. Ten
minutes of operation on one power supply is allowed for the I/O drawer for
service.
No A secondary drawer will not power on. Go to step 8.
Yes This ends the procedure. Go to ″Map 0410: Repair Checkout″ in the
Diagnostic Information for Multiple Bus Systems
8. Are all SPCN cables from and to the secondary I/O drawer(s) connected
properly and firmly seated?
No Go to step 22 on page 99.
Yes Go to step 9.
9. Is only one secondary I/O drawer not powering on?
No Go to step 23 on page 99.
Yes Go to step 17 on page 99.
10. Replace the following:
a. Power distribution card
b. Drawer indicator panel
c. Fan monitoring card
d. Both power supplies
e. I/O planar.
11. Does the I/O drawer power on?
No Go to step 15 on page 99.
Yes Go to step 12.
12. Go to step 7.
98 Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM S85 pSeries 680 and is the answer not in the manual?

IBM S85 pSeries 680 Specifications

General IconGeneral
BrandIBM
ModelS85 pSeries 680
CategoryServer
LanguageEnglish

Related product manuals