Symptom Action
You have been directed to MAP 1540 by the
SRC tables and the SRC is B0061305 or
B0061306.
1. Service processor card
2. I/O planar
You have been directed to MAP 1540 for any
other reason.
1. Boot device SCSI card
2. Boot device SCSI cable
3. Service processor card
4. I/O planar
5. Drawer indicator panel
6. Fan monitoring card
7. Both power supplies
8. Power distribution board.
Was the boot successful?
No Reinstall the next part in the list and return to the beginning of this step.
Continue repeating this process until a part causes the boot to be successful.
If you have replaced all the items listed above and the boot is not successful,
check any external devices and cabling. If you do not find a problem, contact
your next level of support for assistance.
Yes Go to “Step 1540-23” on page 128.