Reference Code
(IPL SRC)
Description/Function Performed Action/ Possible Failing FRU
C1yx 1030 Loading service processor system firmware from service
processor device
Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C1yx 1050 Loading service processor system firmware from
non-service processor device
Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C1yx 2001 Service processor setting up to test and load system
processor
Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C1yx 2002 Service processor testing system processor and main
storage
Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C1yx 2003 Service processor loading system processor Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C100 2034 Firmware (system) initialized, control passed to system
processor
Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C1yx 2050 Service processor waiting for load source device Go to MAP 1540: Minimum
Configuration on page 117
C1yx 2060 Service processor started a read command from load
source
Go to MAP 1540: Minimum
Configuration on page 117
C1yx 2090 Service processor completed a read command from load
source
Go to MAP 1540: Minimum
Configuration on page 117
C1yx 80xx Service processor/operator panel communication in
progress
Go to MAP 1540: Minimum
Configuration on page 117
C1yx 805x Service processor loading operator panel firmware Go to MAP 1540: Minimum
Configuration on page 117
C1yx 8C5x VPD table data transferring from the operator panel to
the service processor.
Go to MAP 1540: Minimum
Configuration on page 117
C1yx B1xx Basic assurance test completed on service processor Go to MAP 1540: Minimum
Configuration on page 117
C100 D009 Firmware (system) running initialization Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
C3yx xxxx System processor or main storage diagnostic in progress Go to MAP 1540: Minimum
Configuration on page 117; follow the
MAP steps to perform the system
rack minimum configuration.
Chapter 4. Checkpoints
139