Table 5. Firmware Error Codes. (continued)
Error Code Description Action/ Possible Failing FRU
21A000xxx SCSI device errors
Notes:
1. Before replacing any system
components:
a. Ensure that the controller and
each device on the SCSI bus is
assigned a unique SCSI ID.
b. Ensure SCSI bus is properly
terminated.
c. Ensure SCSI signal and power
cables are securely connected
and not damaged.
2. The location code information is
required to identify the ID of SCSI
device failures, as well as to indicate
the location of the controller to
which the device is attached. Check
the system error logs to determine
the location code information
associated with the error code.
21A00001 Test unit ready failed - hardware error Refer to the notes in error code
21A000xxx.
1. Replace the SCSI device.
2. Replace the SCSI cable.
3. Replace the SCSI controller.
21A00002 Test unit ready failed - sense data
available
Refer to the notes in error code
21A000xxx.
1. Replace the media (removable
media devices).
2. Replace the SCSI device.
21A00003 Send diagnostic failed Refer to the notes in error code
21A000xxx. Replace the SCSI device.
21A00004 Send diagnostic failed - DevOfl cmd Refer to the notes in error code
21A000xxx. Replace the SCSI device.
21E00xxx SCSI tape Refer to 21A00xxx for a description and
repair action for the xxx value.
21ED0xxx SCSI changer Refer to 21A00xxx for a description and
repair action for the xxx value.
21EE0xxx Other SCSI device type Refer to 21A00xxx for a description and
repair action for the xxx value.
21F00xxx SCSI CD-ROM Refer to 21A00xxx for a description and
repair action for the xxx value.
21F20xxx SCSI read/write optical Refer to 21A00xxx for a description and
repair action for the xxx value.
22000001 PCI Ethernet BNC/RJ-45 or PCI
Ethernet AUI/RJ-45 adapter internal
wrap test failure
Replace the adapter. See note 5 on
page 157 for location code information
related to this error.
164 Service Guide