Table 5. Firmware Error Codes. (continued)
Error Code Description Action/ Possible Failing FRU
26020007 Failed to allocate bus resources to PCI
adapter
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update if
available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter.
5. Check for system firmware updates.
Apply if update available.
6. Replace power supply.
7. Replace I/O board (See notes on
page 157.)
26800Axy MX-PCI bridge BIST Failure The problem is associated with bridge
y in I/O drawer x.
Replace I/O drawer planar.
x indicates the I/O drawer number.
If x=_, then the I/O drawer is:
x = I/O drawer
1=0
2=1
3=2
4=3
See AIX and Physical Location Code
Reference Tables on page 48 in
Chapter 1, for location codes.
26800Cxx Machine check occurred.
1. Replace the part identified by the
location code associated with this
error code.
2. If the location code associated wth
this error code identifies an adapter,
and replacing the adapter does not
correct the problem, replace the I/O
drawer planar.
See note 5 on page 157 for location
code information related to this error.
Chapter 5. Error Code to FRU Index