Reference
Code
Description/Action
(Perform all actions before exchanging Failing
Items)
Failing Item
1304 Power supply P05 fault
A fault has been detected for power supply P05. If
the LED on a bulk power supply is not on or is
blinking, it may be the failing item. The LED not
on may be the only indication of a failure.
Exchange the bulk power supply to correct this
problem.
Bulk power supply P05
Location: U1.2-V5
1308 Regulator R01 fault
A fault has been detected for regulator R01.
Programmable regulator assembly R01
Location: U1.1-P2-V1
1309 Regulator R02 fault
A fault has been detected for regulator R02.
Programmable regulator assembly R02
Location: U1.1-P2-V2
130A Regulator R03 fault
A fault has been detected for regulator R03.
Programmable regulator assembly R03
Location: U1.1-P2-V3
130B Regulator R04 fault
A fault has been detected for regulator R04.
Programmable regulator assembly R04
Location: U1.1-P2-V4
130C Regulator R05 fault
A fault has been detected for regulator R05.
Programmable regulator assembly R05
Location: U1.1-P2-V5
130D Regulator R06 fault
A fault has been detected for regulator R06.
Programmable regulator assembly R06
Location: U1.1-P2-V6
130E Regulator R07 fault
A fault has been detected for regulator R07.
Programmable regulator assembly R07
Location: U1.1-P2-V7
130F Regulator R08 fault
A fault has been detected for regulator R08.
Programmable regulator assembly R08
Location: U1.1-P2-V8
1310 Regulator R09 fault
A fault has been detected for regulator R09.
Programmable regulator assembly R09
Location: U1.1-P2-V9
1311 Regulator R10 fault
A fault has been detected for regulator R10.
Programmable regulator assembly R10
Location: U1.1-P2-V10
131C Regulator R21 error
A fault detection failure occurred for regulator
R21.
1. Processor regulator card R21, Slot M04
Location: U1.1-P1-V1
2. SPCN card
Location: U1.1-P2-X1
1xxx
Chapter 5. Error Code to FRU Index 195