(Perform all actions before exchanging Failing
Items)
Failing Item
6A38 A regulator fault detection failure occurred for
regulator 2.
1. Programmable regulator assembly R02
Location: U1.1-P2-V2
2. Go to MAP 1520: Power on page 88.
3. ac box
Location: U1.2-V7
6A58 Regulator fault
A regulator fault detection failure occurred for
regulator 3. The regulator or the SPCN card can
causes this fault.
1. Programmable regulator assembly R03
Location: U1.1-P2-V3
2. SPCN card
Location: U1.1-P2-X1
3. ac box
Location: U1.2-V7
7000 Air moving device 1 fault
A problem was detected with an air moving
device, which can be caused by an air moving
device not being installed or operating at the
wrong speed. The SPCN card could be defective.
Change the failing items one at a time.
1. Blower 1, B01
Location: U1.2-F1
2. SPCN card
Location: U1.1-P2-X1
7001 Air moving device 2 fault
A problem was detected with an air moving
device, which can be caused by an air moving
device not being installed or operating at the
wrong speed. The SPCN card could be defective.
Change the failing items one at a time.
1. Blower 2, B02
Location: U1.2-F2
2. SPCN card
Location: U1.1-P2-X1
7002 Air moving device 3 fault
A problem was detected with an air moving
device, which can be caused by an air moving
device not being installed or operating at the
wrong speed. The SPCN card could be defective.
Change the failing items one at a time.
1. Blower 3, B03
Location: U1.2-F3
2. SPCN card
Location: U1.1-P2-X1
7003 Air moving device 4 fault
A problem was detected with an air moving
device, which can be caused by an air moving
device not being installed or operating at the
wrong speed. The SPCN card could be defective.
Change the failing items one at a time.
1. Blower 4, B04
Location: U1.2-F4
2. SPCN card
Location: U1.1-P2-X1
7101 Power supply failure
The ac power supply module (ac box) reported a
fault.
1. ac box
Location: U1.2-V7
1xxx
200
Service Guide

Table of Contents