Reference Code Description/Action
Perform all actions before exchanging Failing Items
Failing Item
2425 Main storage failure
A memory card at the specified location is faulty.
Probability is mandatory.
Record function code 19 from the operator panel. This
function code is the CCIN identifier, which is used to
determine the processor or memory card type. To get the
part number for the failing card, find the CCIN number in
the parts tables under Electronic Cards on page 556.
Memory Card, M09
Location: U1.1-P1-M5
AIX Location Code: 00-00
2426 Main storage failure
A memory card at the specified location is faulty.
Probability is mandatory.
Record function code 19 from the operator panel. This
function code is the CCIN identifier, which is used to
determine the processor or memory card type. To get the
part number for the failing card, find the CCIN number in
the parts tables under Electronic Cards on page 556.
Memory Card, M10
Location: U1.1-P1-M6
AIX Location Code: 00-00
2427 Main storage failure
A memory card at the specified location is faulty.
Probability is mandatory.
Record function code 19 from the operator panel. This
function code is the CCIN identifier, which is used to
determine the processor or memory card type. To get the
part number for the failing card, find the CCIN number in
the parts tables under Electronic Cards on page 556.
Memory Card, M11
Location: U1.1-P1-M7
AIX Location Code: 00-00
2428 Main storage failure
A memory card at the specified location is faulty.
Probability is mandatory.
Record function code 19 from the operator panel. This
function code is the CCIN identifier, which is used to
determine the processor or memory card type. To get the
part number for the failing card, find the CCIN number in
the parts tables under Electronic Cards on page 556.
Memory Card, M12
Location: U1.1-P1-M8
AIX Location Code: 00-00
2429 Main storage failure
A memory card at the specified location is faulty.
Probability is mandatory.
Record function code 19 from the operator panel. This
function code is the CCIN identifier, which is used to
determine the processor or memory card type. To get the
part number for the failing card, find the CCIN number in
the parts tables under Electronic Cards on page 556.
Memory Card, M13
Location: U1.1-P1-M9
AIX Location Code: 00-00
B4xx
Chapter 5. Error Code to FRU Index 223

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM S85 pSeries 680 and is the answer not in the manual?

IBM S85 pSeries 680 Specifications

General IconGeneral
BrandIBM
ModelS85 pSeries 680
CategoryServer
LanguageEnglish

Related product manuals