This subfunction is returned when the user selects ** for subfunction and
activates Enter. This is used to cancel a pending subfunction 2 - 5 concurrent
maintenance operation. SPCN responds with an EPF 1 - 5 to clear any other
subfunction range previously enabled.
01 System Power On
This command causes a Rack Power On command to be transmitted to the
network, if the CEC is powered on. This function is used to restore power to
racks turned off or faulted off after concurrent repairs have been completed.
02 Blower Power Off
This function is used to select a concurrent blower power off operation. SPCN
responds by enabling subfunction range F0 - F3 to select the blower to be
powered off.
03 Bulk Power Off
This function is used to select a concurrent bulk power off operation. SPCN
responds by enabling subfunction range B0 - B5 to select the bulk to be
powered off.
04 Blower Power On
This function is used to select a concurrent blower power on operation. SPCN
responds by enabling subfunction range F0 - F3 to select the blower to be
powered on.
This function is only needed if the wrong blower is powered off. A concurrently
repaired blower is automatically started after the blower is inserted.
05 Bulk Power On
This function is used to select a concurrent bulk power on operation. SPCN
responds by enabling subfunction range B0 - B5 to select the bulk to be
powered off.
This function is only needed if the wrong bulk is powered off. A concurrently
repaired bulk is automatically started after the bulk is installed.
F0 - F3 Select Blower
This subfunction is used to select the blower for the previously selected
concurrent repair operation. If accepted, SPCN performs the operation and
disables this subfunction range. A function 5 SRC is displayed when the blower
is turned off and removed when the blower is installed.
B0 - B5
Select Bulk
This subfunction is used to select the bulk for the previously selected
concurrent repair operation. If accepted, SPCN performs the operation and
disables this subfunction range. A function 5 SRC is displayed when the bulk is
turned off and removed when the bulk is installed.
602 Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM S85 pSeries 680 and is the answer not in the manual?

IBM S85 pSeries 680 Specifications

General IconGeneral
BrandIBM
ModelS85 pSeries 680
CategoryServer
LanguageEnglish

Related product manuals