Table 1. Server features and specifications (continued)
RAID controllers:
v ServeRAID C105 supports up to
eight SATA ports
support for RAID level 0, 1 and
10
support 3.5-inch SATA 3TB
HDDs
support HDD Simple swap and
Hot swap
support 4 SATA HDDs in
default (can be upgraded to 8
SATA HDDs via FoD key)
Note:
v In 2.5" system, two internal SAS
cable connecting SAS RAID
controller to SAS hard drive
backplane. One type of backplanes
will be used to support eight 2.5"
hot -swap HDDs. In addition, the
system will use 2 types of
backplanes to support sixteen 2.5
hot-swap HDDs.
v In 3.5" system, two internal SAS
cable is required to support eight
3.5" hot-swap HDDs with the
required backplane.
PCI and PCI-X expansion slots:
v Six PCI-e expansion slots on the
system board
Slot 1: PCI Express 3.0 x8;
full-height, half-length (requires
second processor)
Slot 2: PCI Express 3.0 x8 ;
full-height, full-length
Slot 3: PCI Express 3.0 x8 (x4
wired); full-height, half-length
Slot 4: PCI Express 3.0 x16 (x8
wired); full-height, full-length
Slot 5: Gen2 PCI Express x4 (x1
wired); full-height, half-length
Slot 6: Gen2 PCI Express x8 (x4
wired); full-height, half-length,
has PCI-X capability by using a
PCI-e (of IBM System x3500 M4
TYpe 7383) to PCI-X converter
kit
v One PCI-X Slot (optional):
64-bit/133MHz
Environment:
The IBM System X3300 compute
node complies with ASHRAE class
A3 specifications.
v Power on:
Temperature: 5°C - 40°C (41°F -
104°F) up to 950mm (3,117ft)
Above 950m, de-rated
maximum air temperature 1C /
175m
Humidity, non-condensing:
-12°C dew point (10.4°F) and 8%
- 85% relative humidity
Maximum dew point: 24°C
(75°F)
Maximum altitude: 3050 m
(10,000 ft) & 5°C - 28°C (41°F -
82°F)
Maximum rate of temperature
change: 5°C/hr (41°F/hr) for
tape drive, 20°C/hr (68°F/hr)
for HDDs
v Power off:
Temperature: 5°C to 45°C (41°F -
113°F)
Relative humidity: 8% - 85%
Maximum dew point: 27°C
(80.6°F)
v Storage (non-operating)
Temperature: 1°C to 60°C
(33.8°F - 140°F)
Altitude: 3050 m (10,000 ft)
Relative humidity: 5% - 80%
Maximum dew point: 29°C
(84.2°F)
v Shipment (non-operating)
Temperature: -40°C to 60°C
(-40°F - 140°F)
Altitude: 10,700 m (35,105 ft)
Relative humidity: 5% - 100%
Maximum dew point: 29°C
(84.2°F)
v Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server. For
information about the limits for
particulates and gases, see
Particulate contamination.
Heat output:
Approximate heat output in British
thermal units (Bts):
v Minimum configuration: 392 Btu
per hour (ac 115 watts)
v Maximum configuration: 2900 Btu
per hour (ac 850 watts)
Integrated functions:
v Integrated Management Module II
(IMM2), which provides service
processor control and monitoring
functions, video controller, and
remote keyboard, video, mouse,
and remote hard disk drive
capabilities
v Onboard Intel Powerville Gigabit
Ethernet controller with Wake on
LAN support. The controller
provides up to four ports when the
optional Feature on Demand (FoD)
feature is activated.
v Combine "Intel PCH SAS/SATA
RAID controller which supports
for RAID levels 0, 1 and 10 with
SW RAID controller - ServeRAID
C105
v Light path diagnostics
v Eight Universal Serial Bus (USB)
2.0 ports:
Two on the front of the chassis
Four on the rear of the chassis
Two internal USB ports: one is
for option USB flash device with
embedded hypervisor, one is for
option USB tape drive
v One serial connector
v One D-Sub VGA connector
Power supply:
v One fixed 460-watt power supply
None support AEM function
None support graphic card
For two microprocessors
installed, the maximum HDD is
up to 4 and the maximum PCIe
cards is up to 3
v Up to two hot-swap power supply
for redundant supply
550-watt ac
Note:
1. None support graphic card
2. The maximum PCIe card is
up to 3 when two
microprocessors installed for
550-watt ac.
750-watt ac
Chapter 1. The IBM System x3300 M4 Type 7382 server 7

Table of Contents

Other manuals for IBM System x3300 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3300 M4 and is the answer not in the manual?

IBM System x3300 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3300 M4
CategoryServer
LanguageEnglish

Related product manuals