PCI-e slots on the riser-card and the system board, the microprocessor to which
each slot is connected, and the supported adapters that you can install in each
slot:
Table 12. PCI riser slots supported configurations
PCI-X riser-card
assembly
PCI-e slot
number
Microprocessor
to which the
slot is connected Configuration 1 Configuration 2
1 1 Microprocessor 1 PCI-e Gen2 x16
(x16
mechanically)
full-height,
half-length
adapter
PCI-e Gen2 x8
(x16
mechanically)
full-height,
half-length
adapter
1 2 Microprocessor 1 N/A PCI-e Gen2 x8
(x16
mechanically)
low-profile
adapter
2 3 Microprocessor 1 PCI-e Gen2 x4
low-profile,
internal RAID
adapter
PCI-e Gen2 x4
low-profile,
internal RAID
adapter
Note: PCI-e slot 3 on PCI-X riser-card assembly 2 is reserved for an optional internal RAID
adapter. Do not install any internal RAID adapter in PCI riser-card assembly 1.
Note: While installing 16 GB 1.5 Volt/ 32 GB 1.35 Volt, please refers to the table
of fan configuration instruction.
Table 13. Fan Configuration Instruction
Fans Conditions
2 and
Rear
fan
Standard for all systems
3
1. When the second microprocessor is populated, the fan is included in the
second microprocessor kit, P/N: 00D2581 ~ 00D2589. Or
2. When more than 2 PCI-e adapters have been installed on the system, the fan
(P/N: 00D2593) will be available separately.
1 Optional redundant fan (P/N: 00D2593)
Attention: When fan 3 is installed and 16 GB 1.5V / 32 GB 1.35V DIMMs are
installed, fan 1 must also be populated.
v The following table lists the option part numbers and CRU part numbers for the
network adapters.
Table 14. Network adapters
Network Adapters
Description
Option part
number
CRU part
number
QLogic 4Gb PCIe FC single-port HBA 39R6525 39R6526
QLogic 4Gb PCIe FC dual-port HBA 39R6527 39R6528
NetXtreme II 1000 express Ethernet adapter 39Y6066 39Y6070
80 System x3300 M4 Type 7382: Installation and Service Guide