Table 28. System power faults (continued)
Boot
code Message
Potential defective
component
Corresponding
IMM Event ID
Corresponding IMM
log message
16 ENET_1_5VAUX_PGOOD System Board 80070603-0701ffff Sensor MainBrd ENET
VRD has transitioned to
non-recoverable.
17 DIMM_3_3VAUX_PGOOD System Board 80070603-0701ffff Sensor MainBrd VRD
has transitioned to
non-recoverable.
18 MEM1A_VDDQ_PGOOD System Board 80070603-0701ffff Sensor DIMM 1-6 VRD
has transitioned to
non-recoverable.
19 MEM1B_VDDQ_PGOOD System Board 80070603-0701ffff Sensor DIMM 7-12 VRD
has transitioned to
non-recoverable.
1A MEM2A_VDDQ_PGOOD System Board 80070603-0701ffff Sensor DIMM 13-18
VRD has transitioned to
non-recoverable.
1B MEM2B_VDDQ_PGOOD System Board 80070603-0701ffff Sensor DIMM 19-24
VRD has transitioned to
non-recoverable.
1C MEM3A_VDDQ_PGOOD CPU/Memory Tray 80070603-2B01ffff Sensor DIMM 25-30
VRD has transitioned to
non-recoverable.
1D MEM3B_VDDQ_PGOOD CPU/Memory Tray 80070603-2B01ffff Sensor DIMM 31-36
VRD has transitioned to
non-recoverable.
1E MEM4A_VDDQ_PGOOD CPU/Memory Tray 80070603-2B01ffff Sensor DIMM 37-42
VRD has transitioned to
non-recoverable.
1F MEM4B_VDDQ_PGOOD CPU/Memory Tray 80070603-2B01ffff Sensor DIMM 43-48
VRD has transitioned to
non-recoverable.
20 OC_FAULT System Board 80070603-0701ffff Sensor System VRD has
transitioned to
non-recoverable.
28 CPU1_VCORE_PGOOD System Board 80070603-0701ffff Sensor CPU1 VRD has
transitioned to
non-recoverable.
29 CPU2_VCORE_PGOOD System Board 80070603-0701ffff Sensor CPU2 VRD has
transitioned to
non-recoverable.
2A CPU3_VCORE_PGOOD CPU/Memory Tray 80070603-2B01ffff Sensor CPU3 VRD has
transitioned to
non-recoverable.
2B CPU4_VCORE_PGOOD CPU/Memory Tray 80070603-2B01ffff Sensor CPU4 VRD has
transitioned to
non-recoverable.
2C CPU1_VPLL_PGOOD System Board 80070603-0701ffff Sensor CPU1 VRD has
transitioned to
non-recoverable.
Appendix B. Boot code display error codes 319