40000075-00000000 The measured power value exceeded the power cap value.
Explanation: The measured power value has exceeded the power cap value.
Severity: Warning
Alert Category: Warning - Power
Serviceable: No
CIM Information: Prefix: IMM and ID: 0117
SNMP Trap ID: 164
Automatically notify Support: No
User response:
v Make sure IMM firmware is at the latest level.
v Raise the system power cap value or adjust the system workload to be less than the currently applied power cap.
40000076-00000000 The new minimum power cap value exceeded the power cap value.
Explanation: Minimum Power Cap exceeds Power Cap
Severity: Warning
Alert Category: Warning - Power
Serviceable: No
CIM Information: Prefix: IMM and ID: 0118
SNMP Trap ID: 164
Automatically notify Support: No
User response: User may need to adjust the power cap value to be greater or equal to the minimum power cap.
40000077-00000000 Power capping was activated by user [arg1].
Explanation: The power capping control has been enabled.
Severity: Info
Alert Category: none
Serviceable: No
CIM Information: Prefix: IMM and ID: 0119
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
40000075-00000000 • 40000077-00000000
Appendix D. Integrated management module II (IMM2) error messages 389