80010701-1408ffff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a microprocessor and memory expansion tray voltage
regulator has risen above normal.
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010701-1409ffff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a microprocessor and memory expansion tray voltage
regulator has risen above normal.
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010701-140affff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted.
Explanation: IMM has detected that the temperature of a microprocessor and memory expansion tray voltage
regulator has risen above normal.
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.