EasyManua.ls Logo

IBM System x3750 M4 Type 8722 - Page 426

IBM System x3750 M4 Type 8722
694 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80010b01-1403ffff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted.
Explanation: The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown
has occurred.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010b01-1404ffff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted.
Explanation: The temperature for a system board voltage regulator has risen above its threshold. A hard shutdown
has occurred.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010b01-1403ffff 80010b01-1404ffff
410
System x3750 M4 Types 8722 and 8733: Installation and Service Guide

Table of Contents

Related product manuals