80010b01-1409ffff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted.
Explanation: The temperature for a microprocessor and memory expansion tray voltage regulator has risen above its
threshold. A hard shutdown has occurred.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010b01-140affff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted.
Explanation: The temperature for a microprocessor and memory expansion tray voltage regulator has risen above its
threshold. A hard shutdown has occurred.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80010b01-1409ffff • 80010b01-140affff
Appendix D. Integrated management module II (IMM2) error messages 413