80070201-0303ffff Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 3 temperature Sensor has transitioned to critical.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070201-0304ffff Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: IMM has detected a CPU 4 temperature Sensor has transitioned to critical.
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070202-0701ffff Sensor [SensorElementName] has transitioned to critical from a less severe state.
Explanation: The Planar Fault sensor has detected a problem with the system board.
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 1
Automatically notify Support: No
User response: Complete the following steps:
1. Remove any recently installed components.
2. Try to power on the node.
v If the node successfully powers on, complete the following steps:
a. Check the ServerProven website to make sure that recently installed components are compatible with the
compute node.
b. Inspect the previously installed components for physical damage.
80070201-0303ffff 80070202-0701ffff
418
System x3750 M4 Types 8722 and 8733: Installation and Service Guide