800b0108-1381ffff Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Power Supply Redundancy has been lost.
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
1. Power Unit :Check if Power Supply is missing, unplugged.
2. Check the power supply LEDs, see "Power-supply LEDs"
3. Replace the affected power supply.
800b010a-1e81ffff Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 1
800b010a-1e82ffff Redundancy Lost for [RedundancySetElementName] has asserted.
Explanation: Fan Redundancy has been lost.
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response: Replace Fan 2
800b0108-1381ffff 800b010a-1e82ffff
Appendix D. Integrated management module II (IMM2) error messages 429

Table of Contents

Related product manuals