Chapter 5. Preparing the hardware 149
򐂰 Intel Virtualization Technology (Default: Enable)
This option enables the processor hardware acceleration feature for virtualization. See
“Intel Virtualization Technology” on page 25 for more information.
򐂰 Enable SMX (Default: Disabled)
This option enables Safer Mode Extensions.
򐂰 Hardware Prefetcher (Default: Enabled)
This option enables Hardware Prefetcher. Lightly threaded applications and some
benchmarks can benefit from having the Hardware Prefetcher enabled.
򐂰 Adjacent Cache Prefetcher (Default: Enabled)
This option enables Adjacent Cache Prefetcher. Lightly threaded applications and some
benchmarks can benefit from having the Adjacent Cache Prefetcher enabled.
򐂰 DCU Streamer Prefetcher (Default: Enabled)
This option enables DCU Streamer Prefetcher. Lightly threaded applications and some
benchmarks can benefit from having the DCU Streamer Prefetcher enabled.
򐂰 DCU IP Prefetcher (Default: Enabled)
This option enables the DCU IP Prefetcher. This option is typically best left enabled for
most environments. Some environments may benefit from having it disabled (for example,
Java).
򐂰 Cores in CPU Package (Default: All)
This option sets the number of processor cores to be activated within each CPU package.
You may want to change your CPU cores to lower your power consumption or to meet
software licensing requirements.
򐂰 QPI Link Frequency (Default: Max Performance)
This option sets the operating frequency of the processor’s QPI link:
Minimal Power provides less performance for better power savings.
Power Efficiency provides best performance per watt ratio.
Max performance provides the best system performance.
5.3.3 Memory settings
The Memory settings panel provides the available memory operation options, as shown in
Figure 5-17.
Figure 5-17 UEFI Memory system settings panel

Table of Contents

Other manuals for IBM X3850 X6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM X3850 X6 and is the answer not in the manual?

IBM X3850 X6 Specifications

General IconGeneral
ChipsetIntel C602J
Network ControllerIntegrated quad-port Gigabit Ethernet
ProcessorUp to four Intel Xeon E7-4800 v2 series processors or Intel Xeon E7-8800 v2 series processors
MemoryUp to 6 TB of DDR3 ECC Registered DIMMs (RDIMMs) or Load-Reduced DIMMs (LRDIMMs)
Form Factor4U rack server
StorageUp to 24x 2.5" hot-swap SAS/SATA HDDs or SSDs
Expansion SlotsUp to 11 PCIe 3.0 slots
Power SupplyUp to four 1400W or 900W hot-swap power supplies
Memory TypeDDR3 RDIMM/LRDIMM
Storage ControllerServeRAID M5210 SAS/SATA controller
RAID SupportRAID 0, 1, 5, 6, 10, 50, 60
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware