EasyManuals Logo
Home>IBM>Server>X3850 X6

IBM X3850 X6 User Manual

IBM X3850 X6
262 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #241 background imageLoading...
Page #241 background image
Chapter 7. Management 225
You can use MSM to manage local or remote RAID controllers and configure MSM for remote
alert notifications. Also, a command-line interface is available.
To download the latest MegaRAID Storage Manager software and obtain the Installation and
User’s Guide, select the ServeRAID software matrix web page:
http://ibm.com/support/entry/portal/docdisplay?lndocid=SERV-RAID
MegaRAID Storage Manager supports a wide variety of controllers. For a list of the most up to
date information about operating system, server, and adapter support, see the following link:
http://www.ibm.com/support/entry/portal/docdisplay?Indocid=migr-5082327
7.7.1 MegaRAID Storage Manager installation
You must have administrator or root equivalent operating system privileges to install and fully
access the MegaRAID Storage software.
There are four setup options:
򐂰 Complete: This option installs all program features.
򐂰 Client: This option installs the required components to remotely view and configure
servers.
򐂰 Server: This option only installs the required components for remote server management.
򐂰 Stand Alone: This option only installs the required components for local server
management.
7.7.2 Drive states
A drive group is one or more drives that are controlled by the RAID controller.
There are multiple drive states. The following list describes all of the possible drive states:
򐂰 Online:
A drive that can be accessed by the RAID controller and is part of the virtual drive.
򐂰 Unconfigured Good:
A drive that is functioning normally but is not configured.
򐂰 Hot Spare:
A drive that is powered up and ready for use as a spare in case an online drive fails. There
are two Hot Spare drive states: Dedicated and Global.
򐂰 Failed:
A drive that was originally configured as Online or Hot Spare, but on which the firmware
detects an unrecoverable error.
򐂰 Rebuild:
A drive to which data is being written to restore full redundancy for a virtual drive.
򐂰 Unconfigured Bad:
A drive on which the firmware detects an unrecoverable error.
򐂰 Missing:
A drive that was Online but which has been removed from its location.

Table of Contents

Other manuals for IBM X3850 X6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM X3850 X6 and is the answer not in the manual?

IBM X3850 X6 Specifications

General IconGeneral
BrandIBM
ModelX3850 X6
CategoryServer
LanguageEnglish

Related product manuals