Chapter 7. Management 231
IMM setting
To change the CLI mode for the COM port for use with EMS, use the following procedure:
1. Log in to the web interface of the IMM2.
2. Navigate to IMM Management IMM Properties, as seen in Figure 7-32.
Figure 7-32 IMM2 properties pane
3. From the IMM2 properties pane, select the Serial Port tab, as seen in Figure 7-33.
4. Change the CLI mode to CLI with EMS compatible keystroke sequences.
Figure 7-33 IMM2 Serial Redirect/CLI settings