EasyManua.ls Logo

Icom IC-7000 - Page 155

Icom IC-7000
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
146
17
CONTROL COMMAND
17
CW: Clockwise, CCW: Counter Clockwise
Command table (continued)
1A 050036 Send/read opening message
(0=OFF, 1=ON)
050037 Send/read my call sign setting (10
character: see p. 149 )
050038 Send/read power ON check
(0=OFF, 1=ON)
050039 Send/read current year (2000 to
2099)
050040 Send/read current date (0101 to
1231=Jan. 1st to Dec. 31st)
050041 Send/read current time (0000 to
2359=00:00 to 23:59)
050042 Send/read clock2 function (0=OFF,
1=ON)
050043 Send/read offset time for clock2
function (24001 to 24000=–24:00
to +24:00)
050044 Send/read auto power OFF period
(0=OFF, 1=30 min., 2=60 min.,
3=90 min.)
050045 Send/read TX monitor set
(0=OFF, 1=ON)
050046 Send/read TX monitor gain
(0=0% to 255=100%)
050047 Send/read confirmation beep
(0=OFF, 1=ON)
050048 Send/read band edge beep
(0=OFF, 1=ON)
050049 Send/read beep gain (0=min. to
255=max.)
050050 Send/read beep gain limit (0=OFF,
1=ON)
050051 Send/read RF/SQL control set
(0=Auto, 1=SQL, 2=RF+SQL)
050052 Send/read quick split set (0=OFF,
1=ON)
050053 Send/read split offset –9.999 to
+9.999 MHz (see p. 149 for de-
tails)
050054 Send/read split lock set (0=OFF,
1=ON)
050055 Send/read duplex offset 0.000 to
9.999 MHz for HF (see p. 149 for
details)
050056 Send/read duplex offset 0.000 to
9.999 MHz for 50 MHz band (see
p. 149 for details)
050057 Send/read duplex offset 0.000 to
9.999 MHz for 144 MHz band
(see p. 149 for details)
050058 Send/read duplex offset 0.000 to
9.999 MHz for 430 MHz band
(see p. 149 for details)
050059 Send/read one touch repeater set
(0=DUP–, 1=DUP+)
050060 Send/read auto repeater set
(0=OFF, 1=ON-1, 2=ON-2)
050061 Send/read tuner auto start set
(0=OFF, 1=ON)
050062 Send/read PTT tune set (0=OFF,
1=ON)
1A 050007 Send/read of SSB TX bandwidth
(lower edge) for narrow
(0=100, 1=200, 2=300, 3=500 HZ)
050008 Send/read of SSB TX bandwidth
(higher edge) for narrow (0=2500,
1=2700, 2=2800, 3=2900 HZ)
050009 Twin Peak Filter (0=OFF; 1=ON)
050010 Send/read RTTY mark frequency
(0=1275 Hz, 1=1615 Hz,
2=2125 Hz)
050011 Send/read RTTY shift width
(0=170 Hz, 1=200 Hz, 2=425 Hz)
050012 Send/read RTTY keying polarity
(0=Normal, 1=Reverse)
050013 Send/read CW key speed (0=0.6
WPM to 255=60 WPM)
050014 Send/read CW Pitch setting
(0=300 Hz, 120=900 Hz, in 5 Hz
steps)
050015 Send/read CW side tone level
(0=min. to 255=max.)
050016 Send/read CW side tone level limit
(0=OFF, 1=ON)
050017 Send/read LCD contrast (0=0% to
255=100%)
050018 Send/read LCD bright (0=0%,
255=100%)
050019 Send/read LCD unit bright (0=0%
to 255=100%)
050020 Send/read LCD flicker level (0=0%
to 255=100%)
050021 Send/read switch backlight (0=0%
to 255=100%)
050022 Send/read display type (0=A, 1=B,
2=C)
050023 Send/read display font type
(0=Basic, 1=Italic)
050024 Send/read display font size
(0=Normal, 1=Large)
050025 Send/read meter peak hold
(0=OFF, 1=ON)
050026 Send/read filter pop up indication
for PBT shifting (0=OFF, 1=ON)
050027 Send/read filter pop up indication
for IF filter setting (0=OFF, 1=ON)
050028 Send/read pop up indication for 1
Hz mode (0=OFF, 1=ON)
050029 Send/read pop up indication for
scope center/fix (0=OFF, 1=ON)
050030 Send/read TV pop up indication for
channel Up/Down (0=OFF, 1=ON)
050031 Send/read TV pop up indication for
P.AMP/ATT (0=OFF, 1=ON)
050032 Send/read indication of the voice
TX memory channel names
(0=OFF, 1=ON)
050033 Send/read indication of the keyer
memory names (0=OFF, 1=ON)
050034 Send/read indication of the DTMF
memory names (0=OFF, 1=ON)
050035 Send/read external display setting
(0=1:1.8, 1=1:1.6)
Command Sub command Description Command Sub command Description

Table of Contents

Other manuals for Icom IC-7000

Related product manuals