42
7
DSC OPERATION
D Sending a Test call
You should avoid testing calls on the exclusive DSC
Distress channels and safety calling channels. When
you cannot avoid testing on a Distress or safety
channel, you should indicate that these are test calls.
Normally the Test call would require no further calls
between the two stations involved.
L You can send a Test call to a pre-entered Individual
address, or manually enter the address before
sending. (p. 24)
1. Push .
The “COMPOSE NON-DISTRESS” screen is displayed.
L To display the screen from the Menu screen:
[MENU] > Compose Non-Distress
2. Select “Message Type.
3. Select “Test.
4. Select “Address.”
5. Select an Individual address, or “Manual Input.”
NOTE: When you select “Manual Input” in
this step, push the Keypad key to manually
enter an Individual ID.
6. Select “Call frequency.
7. Select a Call frequency.
8. Push to send a Test call.
“Transmitting Geographical Call” is displayed, and
then “Geographical Call” is displayed.
L See pages 27 and 28 for details of the Software Key
functions in the DSC Task mode.
9. Push , and then to return to
the Main screen.
+
Push
Rotate
+
Push
Rotate
+
Push
Rotate
+
Push
Rotate
+
Push
Rotate
+
Push
Rotate
+
Push
Rotate

Table of Contents