SmartPLC SafeLine AC4S with fieldbus interfaces
>
4.2 ifm CODESYS package
Content
Components of the ifm package .............................................................................................................12
Install the ifm package ............................................................................................................................13
Uninstall ifm package .............................................................................................................................13
► Familiarise yourself with the following CODESYS functions!
Package Manager
→ Online help > CODESYS Development System > Manage packages and licences
>
4.2.1 Components of the ifm package
43264
ifm electronic provides the "CODESYS für ifm SmartPLC SafeLine"package (ifm package for short) for
the programming of the AC4S. The ifm package (file:
ifm_SmartPLC_SafeLine_V1_5_2_10.package) contains the following certified components:
Project templates, project examples, CODESYS safety user manual, CODESYS profiles
Online helps (CODESYS safety, safety network variables)
Description of the device modules, interfaces and additional devices
CODESYS libraries (SF_IO, SafetyPLCopen, SF_LogicalInterfaces, SafetyStandard,
SafetySystemIO, SafetyNetVar, SafetyFSoEMaster, ACnnn_Utils. ACnnnn_SYS_CMD,
IoStandard, SysSafetyIoBase_ifm, IoDrvEtherCAT, IoDrvEtherNetIP, IoDrvAL1020,
IoDrvAL1030 )