SmartPLC SafeLine AC4S with fieldbus interfaces
74
Library
Function block diagram (FBD)
Sequential function chart (SFC)
Instruction list (IL)
Continuous function chart (CFC)
Ladder diagram (LD)
Structured text (ST)
sf_io.library
X
safetystandard.library
X
safetyplcopen.library
X
safetyfsoemaster.library
X
Legend:
X ... is supported
... is not supported
>
8.2.4 Minimum number of AS-i slaves
43101
WARNING!
Altogether 5 AS-i slaves min. have to be installed (standard or safety AS-i slaves) in each of
the AC4S-controlled AS-i network.
> Risk of data loss
If fewer than 5 AS-i slaves are part of the configuration of an AS-i network, provide the
required number of AS-i slaves via virtual AS-i control slaves without function
( SF_OUTcontrol_ASi ( S. 234)).