SmartPLC SafeLine AC4S with fieldbus interfaces
265
>
SF_OUT_local_dual
43092
Device type:
Local I/O interface (output)
Library:
sf_logicalinterfaces.library
Symbol in CODESYS:
>
Description
43287
Logical device to control a 2-channel safe actuator at the local I/O interface
SF_OUT_local_dual detects the Boolean value at the process data signal (OUT_). The logical device
generates a safe Boolean signal and provides the value at the configured output channels of the local
I/O interface (OUT_Channel_A, OUT_Channel_B).
>
Parameter data
43049
Parameter
Data type
Description
Possible values
OUT_Channel_A
INT
Local output to which actuator
channel A is connected.
1
...
4
Local output OUT1
...
Local output OUT4
OUT_Channel_B
INT
Local output to which actuator
channel B is connected.
1 =
...
4 =
Local output OUT1
...
Local output OUT4
DisableLogging
Reserved - settings have no influence on function of the logical device
>
Process data
43009
Parameter
Data type
Description
Possible values
OUT_
SAFEBOOL
Target status of the output / the
outputs
FALSE
SAFE OFF
TRUE
Safe ON