C-COM Satellite Systems Inc. Page 103 of 164
Low Platform Current
The Current Limit for the speeds is calculated using a percentage of the Current Limit @
speed 6 and 9(current limit 6 @ speed 6 is default). See Appendix 1 for the default
current limits for all iNetVu
®
Mobile Platforms.
• Current Limit 8 – 90% of Current Limit 9
• Current Limit 7 – 80% of Current Limit 9
• Current Limit 5 – 90% of Current Limit 6
• Current Limit 4 – 80% of Current Limit 6
Azimuth Limit Switch ST (STOW)
Allows for enabling and disabling the ST (STOW) limit.
A check mark in the box implies the limit has been DISABLED. By default the boxes are
left unchecked. Please be advised that disabling any of these limits should be done
under the direct supervision of a C-COM Satellite Systems Inc. technical support
representative.
Calibrate AZ
Performs automated Azimuth Calibration process. Not applicable on
New Generation platforms i.e. Ka-75V (A0755A), Ka-98H/G/V
(A0985A) ACFLY-1200 (A1210A) etc...
i. Antenna will move CW to a set point.
ii. Antenna will move back in the opposite direction to locate Stow
switch.
iii. Antenna will attempt to locate the cut-off edges of the Azimuth
Stow Switch and center itself.
iv. Azimuth zero position is calculated and the Zero is set at the
zeroed A/D value.

Table of Contents

Other manuals for iNetVu 7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the iNetVu 7000 Series and is the answer not in the manual?

iNetVu 7000 Series Specifications

General IconGeneral
BrandiNetVu
Model7000 Series
CategoryController
LanguageEnglish