C-COM Satellite Systems Inc. Page 60 of 164
3 - Stow Limit
Enabling this function allows for the iNetVu
®
system to trigger the stow limit when
the mechanical stow range of the azimuth is reached. Disabling this limit, may
result in failure to initiate the automatic stow command.
E – Enable Stow Limit
D – Disable Stow Limit
4 –Speed Setting
S The user may configure the slow speed of the azimuth movement. The
slow speed is a basis for the satellite searching procedure.
5 – Current Settings
A software controlled current protection for the Mobile Platform’s azimuth motors.
When any of the Mobile Platform’s motors are moving at the associated speed,
the current drawn to move the motor is monitored and should it exceed the
Current Limit, an error message will appear. For Motor Speeds that are not listed
(Speed 1, 2, 4, 5, 7, 8), the Current Limit for those speeds is calculated using a
percentage of the Current Limit above it. See Appendix 1 for the default current
limits for all iNetVu
®
Mobile Platforms.
• Current Limit 8 – 90% of Current Limit 9
• Current Limit 7 – 80% of Current Limit 9
• Current Limit 5 – 90% of Current Limit 6
• Current Limit 4 – 80% of Current Limit 6
• Current Limit 2 – 90% of Current Limit 3
• Current Limit 1 – 80% of Current Limit 3
I - Configurable Current Limit for Slow Speed (6) movement is displayed under the I: while
the speed under S:
(i.e. I: 07.0 Represents Current Limit of 7 A @ speed 6)