p4 Section 8. Auxiliaries. Version 1.01 CONCEPT IQ. Installation & Programming Manual.
AUXILIARY EVENT TYPE DETAILS
* Auxiliaries 17 to 34 and 57 - “Zone xx Unsealed”, “Door Bell”, “Day Alarm” and “Smoke Det Reset”.
Option 3 (Aux Off when event goes invalid) is not relevant for these Auxiliary Event Types and should not be
selected. These Event Types must be turned Off by an Auxiliary Timer.
No. Auxiliary Event Type: Event On (Valid) when: Event Off (Invalid) when:
39 Zone Bypassed On Arming Any Zone Bypassed (Isolated) on
arming.
Any Area turned off.
40 System Alarm Any system input in alarm. System input acknowledged and no
system input remaining in alarm.
41 Door 1 Alarm
Door Forced or Door Held Alarm on
the specified Door.
Door Forced or Door Held Restored
on the specified Door.
42 Door 2 Alarm
43 Door 3 Alarm
44 Door 4 Alarm
45 Area 1 Auto Arm Prewarn
Auto-Arm Pre-warn started in the
specified Area. (Pre-warn timer
programmed in Address 870)
Auto-Arm Pre-warning expired.
(Area on)
46 Area 2 Auto Arm Prewarn
47 Area 3 Auto Arm Prewarn
48 Area 4 Auto Arm Prewarn
49 Alarm. General Area / Area1
Any Alarm in the specified Area. Area Disarmed.
50 Alarm. Area 2
51 Alarm. Area 3
52 Alarm. Area 4
53 Entry / Exit. General Area / Area 1
Entry or Exit timer running in the
specified Area.
Entry or Exit timer cancelled or
expired in Area.
54 Entry / Exit. Area 2
55
Entry / Exit. Area 3
56 Entry / Exit. Area 4
57 Smoke Detector Reset * "Smoke Detector Reset" operation is
performed at a Terminal.
PIN code, <NEXT>, 99.
(User must have "Master" User Type)
Must be programmed to turn Off by an
Auxiliary Timer.
58 Comms Fail System failed to report. On the next successful dial.
59 Siren Siren active. Siren off.