Section 1. Installation. CONCEPT IQ. Installation & Programming Manual.p6
T1. “AC”.
16V AC Input.
(Connect Green/Yellow Earth wire to T3 “-”)
T4. LAN connections to Terminals. (Up to 4)
Maximum run to furthest LAN Module: 100m.
Total LAN cabling: 150m maximum.
If twisted pair cable is used, DO NOT
combine “Clock” & “Data” on the same pair.
T9. Zone Input /
Auxiliary Output
Expansion Bus Port.
T3. “+” & “-”.
12V Sealed Lead Acid Battery connection.
Maximum Battery capacity: 7 AH
T5. “SPK” & “DET+”
Siren Speaker output.
Maximum load: 8 Ohms
Minimum Speaker rating: 10 Watts.
(i.e. 1 x 8 Ohm Speaker only. Additional
speakers must not be connected in parallel)
NOTE: A 6k8 Resistor must be connected
between “SPK” & “DET+” if Siren speaker not
connected.
T5. “OUT1” & “DET+” (Strobe)
Auxiliary 1 Output.
Normally used for Strobe.
Maximum switched current: 200 mA.
T5. “OUT2” & “DET+”.
Auxiliary 2 Output. General purpose Aux.
May be used for Piezo Siren.
(Program Aux 2 as Event Type 59)
Maximum switched current: 200 mA.
Minimum Cable spec: 14/0.2
Minimum Cable spec: 14/0.2
Minimum Cable spec: 14/0.2
Battery cable supplied.
4 Core Security Cable
recommended. (14/0.2)
CAUTION:
Total current sourced from
“DET+” and “LAN+” must not
exceed 600mA.
Connection Details. Power, Warning devices & LAN
T8. “Aux LAN”.
For temporary
connection of a
Terminal for
diagnostic purposes.
Siren cover Tamper
switch (Normally Closed)
Disclaimer: 1. The manufacturer &/or it’s agents take no responsibility for any damage, financial loss or injury caused to any equipment, property or
persons resulting from the correct or incorrect use of the system or it’s peripherals. The purchaser assumes all responsibility in the use of the system
and it’s peripherals.
2. While every effort has been made to ensure the accuracy of this manual, the manufacturer assumes no responsibility or liability for any errors or
omissions. Due to ongoing development, this manual is subject to change without notice.
JP10. DTMF/Voice
Card Port.
Earth
(Grn/Yell)