8. Power off the system. Again, removing AC power is not necessary but may be advisable
due to safety considerations, or if a riser or other hardware must be moved for access to
the BIOS Recovery jumper.
9. Open the chassis, move hardware if necessary, and restore the recovery jumper position
to "normal operation" pins 1-2. Replace any hardware moved, and close the chassis.
10. Remove Recovery medium.
11. Replug AC cords if removed, and power on the system.
12. Do NOT interrupt the BIOS POST during the first boot.
13. Boot the system into Setup. The Recovery Boot process will reset BIOS settings to
default values.
14. Go to the Setup Main tab (see Figure 20), and set the System Date and System Time to
the correct current settings. Make any other changes that are required in Setup for
example, Boot Order.
Again, before starting to perform a Recovery Boot, be sure to check the BIOS Release Notes
and verify the Recovery procedure shown in the Release Notes.

Table of Contents

Other manuals for Intel S1200V3RP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200V3RP and is the answer not in the manual?

Intel S1200V3RP Specifications

General IconGeneral
BrandIntel
ModelS1200V3RP
CategoryServer Board
LanguageEnglish

Related product manuals