Intel® Server Board S1200V3RP TPS Appendix B: Integrated BMC Sensor Tables
Revision 1.2
- A: Auto-rearm
- M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which is 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED.
Standby
Some sensors operate on standby power. You can access these sensors and/or
generate events when the main (system) power is off but AC power is present.
Table 71. Integrated BMC Core Sensors
Full Sensor
Name
(Sensor name
in SDR)
Contrib.
To
System
Status
Power Unit
Status
(Pwr Unit
Status)
05 - Soft power
control failure
Power Unit
Redundancy
1 (Pwr Unit
Redund)
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
04 – Non-redundant:
sufficient resources.
Transition from
insufficient state.
05 - Non-redundant:
insufficient resources
06 – Redundant:
degraded from fully
redundant state.
07 – Redundant:
Transition from non-
redundant state.
00 - Timer expired,
status only