Intel® Server Board S1200V3RP TPS Platform Management Functional Overview
Revision 1.2
43
See also the Intelligent Platform Management Interface Specification Second Generation v2.0.
6.1.2 Non-IPMI Features
The BMC supports the following non-IPMI features.
In-circuit BMC firmware update
BMC FW reliability enhancements:
- Redundant BMC boot blocks to avoid possibility of a corrupted boot block resulting in
a scenario that prevents a user from updating the BMC
- BMC System Management Health Monitoring
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.
Enable/Disable of System Reset Due CPU Errors
Chassis intrusion detection
Fan speed control
Fan redundancy monitoring and support
Hot-swap fan support
Power Supply Fan Sensors
System Airflow Monitoring
Exit Air Temperature Monitoring
Acoustic management: Support for multiple fan profiles
Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Platform environment control interface (PECI) thermal management support
Memory Thermal Management
DIMM temperature monitoring: New sensors and improved acoustic management using
closed-loop fan control algorithm taking into account DIMM temperature readings
Power supply redundancy monitoring and support
Power unit management: Support for power unit sensor. The BMC handles power-good
dropout conditions.
Intel
®
Intelligent Power Node Manager support
Signal testing support: The BMC provides test commands for setting and getting
platform signal states.
The BMC generates diagnostic beep codes for fault conditions.
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID LED.
It supports secure lockout of certain front panel functionality and monitors button presses.
The chassis ID LED is turned on using a front panel button or a command.
Local Control Display Panel support
Power state retention
Power fault analysis
Intel
®
Light-Guided Diagnostics

Table of Contents

Other manuals for Intel S1200V3RP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S1200V3RP and is the answer not in the manual?

Intel S1200V3RP Specifications

General IconGeneral
BrandIntel
ModelS1200V3RP
CategoryServer Board
LanguageEnglish

Related product manuals