Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 149
8.4.1 RTS options
1>Zone alarm
Yes
The RTS options menu defines conditions that can prevent setting. If a particular
condition below has this option set to Yes, its state affects the “Ready To Set”
state. The system does not allow for areas to set if any of the conditions are true.
For conditions related to areas, the condition is tested for those areas. For
example Zone 5 assigned to area 1 only affects the setting of area 1.
Table 33: Ready To Set conditions
Condition
Description
8.4.1.1 Zone alarm
Active zone
8.4.1.2 Zone panic
Hold-up device active
8.4.1.3 Zone masking
Masking / fault state on input
8.4.1.4 Zone fault
Intrusion detector fault
8.4.1.5 Zone tamper
Tamper in zone
8.4.1.6 Interconnection fault
A critical error caused by communication trouble
between internal panel components
8.4.1.7 Mains fault
Mains fault, including external fault
8.4.1.8 Battery fault
Battery fault, including external fault
8.4.1.9 FTC (Failed to Communicate)
Alarm reporting has failed to deliver events
8.4.1.10 Siren fault
Siren output fault
8.4.1.11 Zone technical
An alarm in the technical zone
8.4.1.12 Keypad fault
A fault reported by keypad
8.4.1.13 Expander fault
A fault reported by remote expander
8.4.1.14 Comms fault
All transmission paths are down (no communication)
8.4.1.15 Engineer reset
Engineer reset requirement
8.4.1.16 Alarms pending
Unacknowledged alarms
8.4.2 Inhibit includes
1>Zone panic
Access level 3
The menu defines which conditions a user with particular access level is allowed
to inhibit. If a particular condition below has this option set to Access level 2 or
Access level 3, a user with this access level can inhibit it using an inhibit menu or
during set.
Table 34: Inhibit inclusion options
Condition
Description
8.4.2.1 Zone panic
Holdup device active
8.4.2.2 Zone masking
Masking / fault state on input

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Advisor Advanced ATS2000A-MM and is the answer not in the manual?

Interlogix Advisor Advanced ATS2000A-MM Specifications

General IconGeneral
BrandInterlogix
ModelAdvisor Advanced ATS2000A-MM
CategoryControl Panel
LanguageEnglish

Related product manuals