42 Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
Remote access
The panel programming can be accessed remotely via configuration software.
A remote access can be gained via IP, GPRS, PSTN or ISDN connection,
depending on the available panel hardware configuration and settings.
Note: Connection via USB cable is not a remote connection.
By default, the menu is accessible remotely with the same installer PIN. The
remote access PIN can be altered using menu “3.1.n.2.2 Remote PIN” on page
85.
Cautions
• Once enabled, remote PIN can be neither disabled nor changed locally, and
the Remote PIN menu is disabled.
• If PIN length gets changed (via “8.7.5 PIN length” described on page 155)
while remote PIN is enabled, the configuration software will not be able to
connect the programmed panel anymore. It will be necessary to delete the panel
configuration in the software, and then recreate it.