Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 239
Options affected by other regulations
ACPO policy
Required settings are all EN 50131 Grade 2 settings with the following
modifications:
5.n.7 Entry alarms, Delayed
8.2.4 Engineer reset, tamper enabled
8.7.7 Alarm confirm:
- AB mode, enabled for all relevant areas
- AB time, 30 min minimum, 60 min maximum
- EE Confirm, enabled
- TA confirm, enabled
Note: ACPO policy allows a higher level manager to become a level 3 user. Also,
level 3 user menu access may be allowed without level 2 user authorization if it is
provided by appropriate written agreement from the customer.
INCERT policy
Required settings:
Isolate for End Users option disabled in 3.2.n.5 User group options
Full Set/Part Set/Unset/Forced Set for Installer disabled in 3.2.n.5 User group
options
8.2.4 Engineer reset, tamper enabled
8.4.1 RTS options, all enabled except FTC, Pending Alarms, and Zone
technical alarm, that are optional
RTS for Battery Fault enabled in 8.4.1 RTS options
Inhibit for Battery Fault disabled in 8.4.2 Inhibit includes
PIN length should be 6 digits minimum. See also “8.7.5 PIN length”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix Advisor Advanced ATS2000A-MM and is the answer not in the manual?

Interlogix Advisor Advanced ATS2000A-MM Specifications

General IconGeneral
BrandInterlogix
ModelAdvisor Advanced ATS2000A-MM
CategoryControl Panel
LanguageEnglish

Related product manuals