52  Advisor Advanced ATSx000A(-IP) Installation and Programming Manual 
When all zones are tested successfully, the following message is displayed. 
 
The test is cancelled if the Clear key is pressed. There is also a maximum time 
limit on the test, set in “8.1.3.3 Walk test time” (see page 140). The test fails if 
this timer expires. If engineer reset fails and inhibit reporting has not been 
enabled when accessing the programming mode then a message is sent to the 
central station to indicate that the test failed (see “Reporting codes used in 
Advisor Advanced” on page 223). 
1.2.5.2 Walk test opts 
 
The Options menu allows setting up the following walk test options. 
1.2.5.2.1 Use internal siren 
 
If the Use internal siren option is set to Yes, each tested zone activation is 
signalled by the internal siren. 
1.2.5.2.2 Use buzzers 
 
If set to Yes, each tested zone activation is signalled by keypad buzzers. 
1.2.5.2.3 Log untested 
 
If the Log untested option is set to Yes, untested zones are recorded in the 
system log. 
1.2.5.2.4 Zone tamper 
 
If the Zone tamper option is set to Yes, the zone tamper is included into the walk 
test. 
1.2.5.2.5 Rkp/Exp tamper 
 
If the Keypad/expander tamper option is set to Yes, the tamper alarms from 
keypads and expanders assigned to this area also have to be tested.