74 Advisor Advanced ATSx000A(-IP) Installation and Programming Manual
2.2.1.n.3.17 EE 2 buzzer
If the option is set to Yes, the buzzer of the selected keypad is active during
entry/exit time 2.
See ā18. Entry/Exit 2ā on page 235 for more details.
2.2.1.n.3.18 1+3 keys
If the option is set to Yes, the combination of 1 and 3 keys allows you to raise a
panic alarm.
See Advisor Advanced User Guide for more details.
This functionality is only available for ATS113x keypads.
2.2.1.n.4 Keypad menu
The keypad menu provides access to the programming menu built-in to the
keypad. For more information, see the appropriate keypad manual.
2.2.1.n.5 Delete keypad
To remove the keypad, press Enter, select OK and press Enter again. The
keypad is deleted.
Note: Before removing a keypad, you should remove any outputs or condition
filters connected to the keypad.