142 Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Appendix A — Error-Handling
Error Types
Classifi ed types of error & status codes for the Error Replies table later in
this appendix.
Type Feature Generates Recovered by
A Minor Error
of command
sequences and
similar.
At Error reporting (cmd
US): Sets error on print
command and sets Orange
LED or Red LED.
At no Error reporting (cmd
UN): Green LED, at print
command
At Error reporting (cmd US):
FEED key or command Reset
^@. See Also command USA.
At no Error reporting (cmd
UN): No recover necessary,
already done.
B Print Stopping
Error.
Sets Orange LED or red
LED.
Feed Key or command Reset
^@.See also command USB.
C Paper End
Stopping
Error.
Sets red LED, at print. Load new media and press
FEED key or command Reset
^@.
D Error of
printing
functionality
and status.
Sets red LED direct,
sometimes blinking.
Manual or automatic
(temperature lowered) measure
or command Reset ^@.
E Status
changes.
No LED change. No recover necessary/Delete
Label from LTS. See also
command USE.
F Unrecoverable
Error.
Sets red LED direct. Power Off/Power On or
command Reset ^@.
G Dump mode. Green LED in dump mode. Feed Key or command Reset
^@.