EasyManua.ls Logo

Intermec EasyCoder C4 - Error Replies

Intermec EasyCoder C4
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual 143
Appendix A — Error-Handling
Error Replies
Explanation of text in the table on the next page:
Error Referred error number divided in Code and Type.
Code Referred error number
Type Letter is a classifying of error.
Description Short human explanation
Error Response... Response depending on Error reporting fl ag controlled by US &
UN.
LED Color of LED-indicator:
Green (GRN)
Red (RED)
Blinking Red (BLNK RED)
Orange (ORA)
Serial Output on Serial line (RS-232 or USB) at error response.
Response at ^ee Output on serial line of error number, if only one error is available.
<LF> 0x0a
<CR> 0x0d
<CRLF> 0x0d + 0x0a
<XON> 0x11
<XOFF> 0x13
<NAK> 0x15
- Nothing happens
[XOFF] Flag for waiting on Error recovery. Default value is <XOFF> =
0x13 , but can be substituted with command eRp1,6,p
3
where p
1
is replacement of <XOFF> and where p
3
is replacement of <XON>.
Example Command eRF,6,N substitutes at error reply <XOFF> with
the character ‘F’ and at error recovery <XON> with the character
‘N’.

Table of Contents

Other manuals for Intermec EasyCoder C4

Related product manuals