Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual 15
Chapter 3—Setting Up the Printer
Some commands may also affect the values of other command, for
example if a confi guration label is printed (see U and UP commands),
the print direction is reset to ZT, and if an R Reference Point command
is executed, the label width (see q command) will be changed.
Example
Let us assume that we will use an EasyCoder C4 for direct thermal
printing. We will print full width Thermal Top labels in the peel-off
mode without using the label taken sensor. The default communication
setup and character set are acceptable.
Thus, a few setup parameters should be changed in the Direct Mode:
Density from 10 to 8
Media feed adjustment from 136 to 110
Label Taken Sensor from enabled to disabled
Enter the following commands:
Command Explanation
CR/LF to start command structure
D8
Set density
j110
Set media feed adjustment for peel-off
operation