84 Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Chapter 7—Commands
O – Options Select
Description This command is used to enable or disable various sensors and
the cutter.
Syntax O[S[,N[,D[,Cnnn|Cb]]]]
Parameters S Enable reverse gap sensing.
N Disable label taken sensor.
D Disable ribbon end sensor
Cnnn Print nnn labels (1-255) before cutting.
Cb Print batch before cutting.
Parameters can be entered in any order. Default: ON
Remarks S: Reverse Gap Sensing Enabled
This parameter reverses the operation of the label gap sensor so
it interprets a blockage of light as a gap between labels or similar.
Before using the S parameter, make sure to load the EasyCoder
C4 printer with the appropriate type of media. By default, the
sensor will interpret blockage of light as a label or similar.
N: Label Taken Sensor Disable
When the label taken sensor is enabled, the communication to
the printer will be BUSY as long as the sensor detects a label
in the outfeed slot. (Does not work with a cutter—use ON to
disable the sensor.)
D: Ribbon End Sensor Disable
The ribbon end sensor (thermal transfer models only) detects
refl ections from the trailing silvery part of the transfer ribbon.
Direct Thermal Mode: If the ribbon end sensor is disabled
parameter, density settings (see D command) are interpreted via a
table that gives an optimized printout for direct thermal printing.
Thermal Transfer Mode: If the ribbon end sensor is enabled,
an error will occur if no refl ection is detected. The density
settings (see D command) are interpreted via a table that gives an
optimized printout for thermal transfer printing.
C: Cutter Enabled
If option C is enabled, cutting will be performed after print.
Commands JF and JB will be disabled, but their values will
remain stored in memory.
If option C is disabled, no cutting will be performed after print.
Commands JF and JB will be enabled. Command f will be
disabled but its value will remain stored in memory.

Table of Contents

Other manuals for Intermec EasyCoder C4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec EasyCoder C4 and is the answer not in the manual?

Intermec EasyCoder C4 Specifications

General IconGeneral
BrandIntermec
ModelEasyCoder C4
CategoryPrinter
LanguageEnglish

Related product manuals