144 Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Appendix A — Error-Handling
Error Replies Table
Error Description Error Response depending on cmd US/UN Response
at cmd
^ee
Code Type command US:
reporting on
command UN:
reporting off
LED Serial LED Serial
00 No Error GRN - GRN - 00<CRLF>
01 A Syntax Error RED <NAK>01[XOFF] GRN - 01<CRLF>
02 B Object exceeds image buff er
border
ORA <NAK>02[XOFF] ORA [XOFF] 02<CRLF>
03 A Data Length error RED <NAK>03[XOFF] GRN - 03<CRLF>
04 A Insuffi cient Memory to Store
Data
RED <NAK>04[XOFF] GRN - 04<CRLF>
05 A Memory Confi guration Error RED <NAK>05[XOFF] GRN - 05<CRLF>
07 C
Out of media, marked with “P”
nnn = numbers of remaining
labels
RED <NAK>07Pnnn[XOFF] RED [XOFF] 07<CRLF>
Out of ribbon, marked with “R”
nnn = numbers of remaining
labels
RED <NAK>07Rnnn[XOFF] RED [XOFF] 07<CRLF>
08 A Form or image name duplicate RED <NAK>08[XOFF] GRN - 08<CRLF>
09 A Form or image not found RED <NAK>09[XOFF] GRN - 09<CRLF>
11 D Print Head Up (Cover Open) RED <NAK>11[XOFF] RED [XOFF] 11<CRLF>
13 E LTS-detection waiting, peel
pause
- <NAK>13[XOFF]
1
- - 13<CRLF>
16 A No form was retrieved before
“?<CRLF> “ was entered.
RED <NAK>16[XOFF] GRN - 16<CRLF>
50 A Does not fi t in area specifi ed RED <NAK>50[XOFF] GRN - 50<CRLF>
51 A Data length too long RED <NAK>51[XOFF] GRN - 51<CRLF>
61 D High Motor temp BLNK
RED
<NAK>61[XOFF] BLNK
RED
[XOFF] 61<CRLF>
62 D High Print Head temp BLNK
RED
<NAK>62[XOFF] BLNK
RED
[XOFF] 62<CRLF>
71 F Wait after Default Setup GRN - GRN [XOFF] 71<CRLF>
72 F Flashing not completed RED <NAK>72[XOFF] RED [XOFF] 72<CRLF>
73 F Download error RED <NAK>73[XOFF] RED [XOFF] 73<CRLF>
81 B Cutter Jammed or Not Installed BLNK
RED
<NAK>81[XOFF] BLNK
RED
[XOFF] 81<CRLF>
89 G Dump mode (after auto
detection)
GRN <NAK>89[XOFF] GRN - 89<CRLF>
1