58 Intermec EasyCoder ESim v4.00—Programmer’s Reference Manual
Chapter 7—Commands
eR – User-Defi ned Error/Status Character Control,
cont.
Example
Command Manual action Reply Comments
US
<ACK> Enable Error Reporting
eRC,2,Q
(Nothing
happens)
Reply error with character ‘C’ and
error NN and at recovery with
character ‘Q’
Open cover C11<CRLF> Manual action generates error 11
Close cover Q00<CRLF> Manual recovery on error 11